INTERLOCKING JOINT PIPES TO SABS SPECIFICATION SANS 677 FOR STORMWATER APPLICATIONS
Pipes
Nominal Diameter mm Inside Diameter ID mm Outside Diameter OD mm Wall Thickness T mm Female Socket S mm Nominal Length L metre Approximate Mass per Metre kg
CLASS 50D
300 292 362 35 17 2.5 0.102
375 369 445 38 17 2.5 0.139
450 445 533 44 17 2.5 0.182
525 514 616 51 19 2.5 0.244
600 611 699 44 19 2.5 0.262
675 685 787 51 20 2.5 0.327
750 762 870 54 20 2.5 0.354
825 830 946 58 22 2.5 0.421
900 913 1041 64 25 2.5 0.509
1050 1060 1180 60 25 2.5 0.569
1200 1190 1340 75 28 2.5 0.798
CLASS 75D
300 392 362 35 17 2.5 0.102
375 369 445 38 17 2.5 0.139
450 445 533 44 17 2.5 0.182
525 514 616 51 19 2.5 0.244
600 611 699 44 19 2.5 0.262
675 685 787 51 20 2.5 0.327
750 742 870 64 20 2.5 0.408
825 810 946 68 22 2.5 0.488
900 893 1041 74 25 2.5 0.568
1050 1040 1180 70 25 2.5 0.632
1200 1170 1340 85 28 2.5 0.864
CLASS 100D
300 292 362 35 18 2.5 0.102
375 369 445 38 17 2.5 0.139
450 445 533 44 17 2.5 0.182
525 514 616 51 19 2.5 0.244
600 587 699 56 19 2.5 0.302
675 647 787 79 20 2.5 0.423
750 718 870 76 20 2.5 0.486
825 788 946 70 22 2.5 0.551
900 869 1041 86 25 2.5 0.650
1050 1000 1180 90 25 2.5 0.807
1200 1150 1340 95 28 2.5 0.960
Please note:
  • Mass per metre is an approximation only.
  • Vula cannot guarantee the exact mass as listed on this table

SPIGOT AND SOCKET PIPES TO SABS SPECIFICATION SANS 677 TYPE SC AND SI FOR STORMWATER OR SEWER APPLICATIONS
Nominal Diameter mm Inside Diameter (ID mm) Outside Diameter (OD mm) Wall Thickness (T mm) Socket Diameter (N mm) Socket Length (B mm) Socket Depth (Y mm) Mass (Kg/Unit) Proof Load (KN/m)
CLASS 50D
300 292 368 38 464 222 114 277 15
375 369 445 38 540 235 127 356 18.8
450 445 533 44 641 257 127 500 22.5
525 514 616 51 730 263 131 659 26.3
600 599 699 50 826 295 138 755 30
675 685 787 51 920 318 139 883 33.8
750 762 870 54 1016 329 139 1046 37.5
825 818 946 64 1086 329 139 1295 41.3
900 913 1041 64 1194 363 139 1452 45
1050 1034 1194 80 1352 391 162 2025 52.5
1200 1187 1365 89 1543 424 168 2566 60
CLASS 75D
300 292 368 38 464 222 114 277 22.5
375 369 445 38 540 235 127 356 28.1
450 445 533 44 641 257 127 500 33.8
525 514 616 51 730 263 131 659 26.3
600 585 699 57 826 295 138 837 39.4
675 673 787 57 920 318 139 878 45
750 738 870 66 1016 329 139 1041 50.06
825 812 946 67 1086 329 139 1343 61.9
900 869 1041 86 1194 363 139 1837 67.5
1050 1004 1194 95 1352 391 162 2326 78.8
1200 1157 1365 104 1543 424 168 2929 90
CLASS 100D
300 292 368 38 464 222 114 277 30
375 369 445 38 540 235 127 356 37.5
450 445 533 44 641 257 127 533 45
525 514 616 51 730 263 131 659 52.5
600 585 699 57 826 295 138 837 60
675 665 787 61 920 318 139 1017 67.5
750 722 870 74 1016 329 139 1338 75
825 780 946 83 1086 329 139 1593 82.5
900 869 1041 86 1194 363 139 1837 105
1050 986 1194 104 1352 391 162 2502 105
1200 1127 1365 119 1543 424 168 3266 120
Please note:
  • Mass per metre is an approximation only.
  • Vula cannot guarantee the exact mass as listed on this table.
  • L = All pipes are 2,5metres in length.
SPIGOT AND SOCKET PIPES TO SABS SPECIFICATION SANS 677 TYPE SI FOR SEWER APPLICATIONS WITH SACRIFICIAL LAYERS
Nominal Diameter mm Inside Diameter (ID mm) Outside Diameter (OD mm) Wall Thickness (T mm) Socket Diameter (N mm) Socket Length (B mm) Socket Depth (Y mm) Mass (Kg/Unit) Proof Load (KN/m)
CLASS 50D
300 266 368 51 464 222 114 140 15
375 343 445 51 540 235 127 180 18.8
450 419 533 57 641 257 127 246 22.5
525 488 616 64 730 263 131 316 26.3
600 573 699 63 826 295 138 363 30
675 659 787 64 920 318 139 424 33.8
750 736 870 67 1016 329 139 497 37.5
825 792 946 77 1086 329 139 603 41.3
900 887 1041 77 1194 363 139 676 45
1050 1008 1194 97 1352 391 162 971 52.5
1200 1149 1365 108 1543 424 168 1207 60
CLASS 75D
300 266 368 51 464 222 114 140 22.5
375 343 445 51 540 235 127 180 28.1
450 419 533 57 641 257 127 246 33.8
525 488 616 64 730 263 131 316 26.3
600 559 699 70 826 295 138 396 39.4
675 647 787 70 920 318 139 424 45
750 712 870 79 1016 329 139 585 50.06
825 786 946 80 1086 329 139 640 61.9
900 843 1041 99 1194 363 139 830 67.5
1050 978 1194 108 1352 391 162 1086 78.8
1200 1119 1365 123 1543 424 168 1370 90
CLASS 100D
300 266 368 51 464 222 114 140 30
375 343 445 51 540 235 127 180 37.5
450 419 533 57 641 257 127 246 45
525 488 616 64 730 263 131 316 52.5
600 556 699 70 826 295 138 396 60
675 639 787 74 920 318 139 480 67.5
750 696 870 87 1016 329 139 610 75
825 754 946 96 1086 329 139 720 82.5
900 843 1041 99 1194 363 139 830 90
1050 960 1194 117 1352 391 162 1154 105
1200 1089 1365 138 1543 424 168 1481 120
All Spigot and Socket Pipes use a Rolling Rubber Ring and no lubrication must be used.
PLEASE NOTE:
  • Mass per metre is an approximation only.
  • Vula cannot guarantee the exact mass as listed on this table.
  • Standard sacrificial layers on sewer pipes are: 300 – 1050 ND – 13mm and 1200 ND – 19m
  • Should you require thicker sacrificial layers, this can be manufactured to order. L = All pipes are 2,5metres in length
REINFORCED MANHOLE RINGS TO SABS SPECIFICATION SANS 1294
Chamber Sections
Nominal Diameter Outside Diameter Inside Diameter Wall Thickness Mass Kg
750 mm 860 mm 750mm 55mm 189/500mm
1000 mm 1130mm 1000mm 65mm 590/m
1250 mm 1400mm 1250mm 75mm 876/m
1500 mm 1670mm 1500mm 85mm 1100/m
Effective Lengths
750 DIA – 250, 500mm – 1000, 1250 & 1500 DIA – 250, 500, 1000mm
Reducer Slab Outside Dia Reduce to Thickness Mass Kg
1000 ND 1130mm 750mm 150mm 234
1250 ND 1400mm 750mm 150mm 397
1500 ND 1670mm 750mm 175mm 810
Cover Slab Outside Dia Reduce to Thickness Mass Kg
750 ND 860mm 560mm 150mm 114
1000 ND 1130mm 560mm 150mm H/D 271
1250 ND 1400mm 560mm 150mm 491
1500 ND 1670mm 560mm 175mm 914
6 Way Base Outside Dia Reduce to Thickness Mass Kg
6 x 160 Knockouts 1130mm 1000mm 480mm 701
Spacer
800 Dia with 560mm Hole 75mm High Mass 045
Frame
800 Tapered to 770mm Dia with 560mm Hole Mass 065
Concrete Lids
560mm Medium Duty Mass 085
560mm Heavy Duty Mass 082
Please note:
  • Mass per metre is an approximation only. Vula cannot guarantee the exact mass as listed on this table.
Vula Civil Engineering Services